AI Insight
Researchers developed BEAM3R, a deep learning framework that rapidly calculates radiation dose distributions for both photon and proton radiotherapy treatments using a beam's-eye-view architecture combined with Mamba-3 state-space models. The system achieved high accuracy with gamma pass rates above 96% for CT-based dose predictions in the DoseRAD2026 challenge, completing calculations in under 25 seconds per case. When using MRI-derived synthetic CT scans instead of actual CT images, accuracy decreased substantially, particularly for proton therapy (75.4% gamma pass rate).
Why it matters
Fast and accurate dose calculations are critical for radiotherapy treatment planning, where precise radiation delivery can improve cancer treatment outcomes while minimizing damage to healthy tissue. This AI-based approach could significantly accelerate treatment planning workflows and enable real-time dose optimization, though the reduced accuracy with MRI-based inputs indicates limitations for MRI-only planning protocols.
Understand the Science
⚠️ Preprint – Noch nicht peer-reviewed
Dieser Artikel wurde noch nicht von unabhängigen Experten begutachtet. Die Ergebnisse sind vorläufig und sollten mit Vorsicht interpretiert werden.
Abstract: To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam’s-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation arranged as channels, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated using a conditional GAN with a SwinUNETR generator and a PatchGAN discriminator. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.
Source: BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction