Researchers tested a new non-invasive glucose monitoring technology called Mid-infrared Optoacoustic Sensing (MiROS) in 30 healthy participants during oral glucose tolerance tests. The technology measured glucose-related changes in tissue optical properties with a mean absolute error of 11.9 mg/dL (10% error rate), performing better than conventional continuous glucose monitors which showed 15.7 mg/dL error and a 10.5-minute delay compared to blood measurements. The MiROS approach showed no comparable time lag and achieved over 99.9% accuracy within clinically acceptable ranges.
Why it matters
This technology could potentially eliminate the need for needle-based glucose sensors that penetrate the skin, offering a truly non-invasive alternative for diabetes management. The absence of time lag compared to current continuous glucose monitors could enable more immediate response to glucose changes, improving diabetes care and reducing patient burden.
⚠️ Preprint – Noch nicht peer-reviewed
Dieser Artikel wurde noch nicht von unabhängigen Experten begutachtet. Die Ergebnisse sind vorläufig und sollten mit Vorsicht interpretiert werden.
Despite transformative advances in continuous glucose monitoring, current continuous glucose monitoring (CGM) still relies on transcutaneous needle-based sensors that measure glucose in the interstitial fluid, which lags behind blood glucose. Mid-infrared optoacoustic sensing (MiROS) has recently demonstrated a sensitivity to glucose changes of a few tens of mg/dL in mice using non-invasive measurements. However, the relation of MiROS to human measurements remains unknown. We conducted a MiROS pilot study in 30 healthy participants undergoing oral glucose tolerance tests and investigated how optoacoustic signals reflect tissue optical-property variations associated with changes in blood glucose concentration. We defined the Optoacoustic Mid-infrared Signal (OMS) as a readout of glucose-induced alterations in tissue optical properties and compared it with reference blood glucose measurements. The OMS corresponded to a mean absolute error (MAE) of 11.9 mg/dL and a mean absolute percentage error (MAPE) of 10% relative to the reference blood analysis. More than 99.9% of paired OMS values were located in zones A and B of the consensus error grid. The study further showed that OMS compared favourably with concurrently acquired CGM measurements, which showed an MAE of 15.7 mg/dL and a MAPE of 12% and exhibited an average time lag of 10.5 min relative to blood glucose. No comparable lag was observed for the OMS. These results support MiROS as a promising framework pointing to a sensor with potential for non-invasive glucose sensing in humans, in the future, and a potential step toward less burdensome glucose monitoring for diabetes management.
Source: Association of Mid-Infrared Optoacoustic Sensing with Glucose Dynamics in Humans