AI Insight
Researchers developed a digital signal processing system in MATLAB/Simulink to analyze ECG signals, detect abnormal heart rhythms, and identify premature ventricular contractions (PVCs). The system uses interpretable rule-based features and achieved 71.43% sensitivity and 81.63% precision for PVC detection on held-out test data from the MIT-BIH Arrhythmia Database, while R-peak detection reached 94.39% sensitivity with approximately 17 ms timing accuracy. The architecture prioritizes algorithmic simplicity and explainability over complex machine learning approaches.
Why it matters
This work demonstrates that lightweight, interpretable algorithms can provide real-time cardiac monitoring with reasonable accuracy, potentially enabling deployment in resource-constrained medical devices or wearable health monitors. The rule-based approach offers clinical transparency, allowing healthcare providers to understand why the system flags specific cardiac events.
⚠️ Preprint – Noch nicht peer-reviewed
Dieser Artikel wurde noch nicht von unabhängigen Experten begutachtet. Die Ergebnisse sind vorläufig und sollten mit Vorsicht interpretiert werden.
Electrocardiogram (ECG) monitoring requires reliable signal preprocessing and interpretable detection of abnormal cardiac activity while maintaining low algorithmic complexity. This study presents an integrated digital signal processing architecture developed in MATLAB/Simulink for ECG preprocessing, QRS and R-peak detection, heart-rate estimation, rhythm classification, and premature ventricular contraction (PVC) detection. Real ECG recordings from the MIT-BIH Arrhythmia Database were used for development and evaluation. The preprocessing stage employs minimum-order elliptic IIR high-pass and low-pass filtering, followed by differentiation, squaring, moving-window integration, thresholding, and R-peak detection. RR intervals derived from detected R peaks are used for instantaneous heart-rate calculation and classification of normal rhythm, bradycardia, and tachycardia. PVC detection uses two interpretable beat-level features, an RR-interval ratio and a QRS-energy ratio, combined through fixed rule-based logic. Three initial 10-s windows containing 18 annotated PVCs were used during algorithm development and threshold selection. After the detector parameters were frozen, evaluation was performed on nine additional non-overlapping 10-s windows containing 56 expert-annotated PVCs from MIT-BIH Records 106, 119, and 200. Using a +/-100 ms event-matching tolerance, the held-out evaluation produced 40 true positives, 9 false positives, and 16 false negatives, corresponding to 71.43% sensitivity, 81.63% precision, and 76.19% F1 score. Across the same nine windows, the R-peak detector achieved 94.39% sensitivity, 99.02% positive predictivity, 96.65% F1 score, and approximately 16.91 ms mean absolute timing error. The results demonstrate the feasibility and limitations of a lightweight and explainable streaming ECG-processing architecture and motivate future work incorporating adaptive decision thresholds and broader patient-independent validation.