Medicine

AI screening tool accurately identifies relevant studies for medical reviews

How the science connects

Natural language p…Systematic reviewMedical informatics

AI Insight

This study validated a two-stage automated screening pipeline combining rule-based filtering and large language models for systematic medical reviews, testing it against three independent physician reviewers on 904 records about platelet reactivity and aspirin resistance. The pipeline achieved near-perfect agreement (PABAK and AC1 scores of 0.94-1.00) with all three reviewers when automatically excluding 670 records (74% of the dataset), but failed to reliably identify records that should be included, missing most articles that human reviewers marked for inclusion. The validation confirms the pipeline can safely automate exclusion decisions but cannot replace human judgment for identifying relevant studies.


Automated screening could significantly reduce the workload of conducting systematic medical reviews by safely eliminating three-quarters of irrelevant studies, though human experts remain essential for identifying which studies to include. This represents a practical middle ground where AI assists rather than replaces human reviewers in evidence synthesis.


Understand the Science

Natural language processing 90 articles Explore Concept → Systematic review Concept coming soon Medical informatics Concept coming soon

⚠️ Preprint – Noch nicht peer-reviewed

Dieser Artikel wurde noch nicht von unabhängigen Experten begutachtet. Die Ergebnisse sind vorläufig und sollten mit Vorsicht interpretiert werden.

Background. Large language models (LLMs) are increasingly used to automate title-abstract screening in systematic reviews, but validation studies typically report sensitivity, specificity, or Cohen’s kappa: metrics that are unstable under the low and unbalanced prevalence that characterises most reviews. No previous study has simultaneously combined a medical topic; a hybrid two-stage pipeline (rules + LLM); a three-way classification with a separately sampled uncertain class; stratified sampling with three independent human reviewers; and dual reporting of prevalence-robust coefficients (PABAK and Gwet’s AC1). Objective. To validate a two-stage automated screening pipeline (a rule-based Python script followed by a reproducible LLM adjudication of uncertain records) against three independent human reviewers in a medical systematic review on high on-treatment platelet reactivity (HTPR), aspirin resistance, and carotid plaque. The primary validation target is the Stage 1 automatic-exclusion decision (670/904 records), which is the workload the pipeline is designed to take off the human reviewer. Methods. From 904 screened records (Stage 1: 131 INCLUDE, 670 EXCLUDE, 94 UNCERTAIN; Stage 2 LLM via API, temperature = 0: 11 INCLUDE, 83 EXCLUDE), a stratified sample of 185 records (50 per Stage 1 stratum + 35 Stage 2; seed = 42) was judged independently and blind to the automated labels by three physicians: E.P. (pipeline designer), D.C. and P.P.B. (both external to the thesis project). Concordance was quantified with sensitivity, specificity, PABAK (q = 3 throughout), Gwet’s AC1, work saved over sampling (WSS), and number needed to read (NNR), AI versus each reviewer and between reviewers, overall and by stratum. Majority labels (2 of 3) are reported as a supplementary panel; they do not replace pairwise tables as the primary reference for sensitivity. Results. On the primary target, Stage1-EXCLUDE concordance was PABAK = AC1 = 1.000 versus E.P. (48/48) and versus D.C. (50/50), and PABAK = 0.940 / AC1 = 0.959 versus Berti (48/50 EXCLUDE, 2 UNCERTAIN). That stratum is 670/904 records (74.1%). Pairwise human agreement was highest between the two external readers (Costazza vs Berti: PABAK = 0.854, AC1 = 0.881) and lower when E.P. was one of the pair (0.703 / 0.774 vs Costazza; 0.621 / 0.702 vs Berti). AI versus each human remained poor (PABAK 0.225 / 0.205 / 0.222). Majority labels on 185 records were 146 EXCLUDE / 27 UNCERTAIN / 4 INCLUDE / 8 NO_MAJORITY. The machine labelled INCLUDE 0 of the 4 majority-INCLUDE records (74, 75, 76, 80). Overall sensitivity was 0.800 versus E.P. (8/10; false negatives 623, 712), 0.500 versus D.C. (1/2; false negative 76), and 0.833 versus Berti (5/6; false negative 76). Versus majority the false-negative count is 1 (record 76); records 623 and 712 are majority EXCLUDE. Stage1-INCLUDE sensitivity of 1.000 is tautological. WSS = 74.1% describes the exclusion stratum only. Conclusions. What this study validates, now with three independent physicians, is automatic exclusion at Stage 1. Fine classification of INCLUDE records is not validated: humans do not agree on which residual records are INCLUDE (triple INCLUDE intersection = record 74 only), Stage 2 missed most of the few human INCLUDE labels it received, and the machine recovered none of the four majority-INCLUDE records. Domain-familiarity as an explanation of INCLUDE divergence remains a hypothesis, not a measured variable.

Source: Validation of a two-stage automated screening pipeline for medical systematic reviews: a stratified concordance study with three independent human reviewers, using PABAK and Gwet's AC1